LSW Lighting Ltd

Start with your contact information

Your privacy matters. Your contact information is used to prepare this layout and is kept within LSW for administering the Quick Lighting Layout service. LSW will not share it with third parties for sales or marketing. No LSW salesperson will contact you unless you request it later on the Report screen. Contact information must be successfully recorded before the lighting tools unlock.
Returning to a saved Quick Layout?Open a .lsw file here first. Saved contact information and the complete Outdoor application/layout will be restored.
Once recorded, the guided setup begins. Expert mode remains available at any time.
Complete all four required contact fields, then save them to unlock the tool.

Project & design constraints

Starting heads are spread across editable field zones. Tennis and Pickleball use symmetric equal-depth fans mirrored across the court. Outdoor Hockey uses true mirrored left/right head ordering on opposite long-side poles. All geometry remains editable.
Sports RecommendationUses the exact IES attached to the selected head, the current field, Class of Play, maximum pole height and LLF. Soccer and Football retain their validated behavior. Baseball retains its validated preset-aware geometry, Point by Point grids and separate infield/outfield criteria. Outdoor Hockey uses its own Class II-IV maintained-average, Max/Min and CV criteria at the 0 ft playing surface, the RP-6-24 centered 14 x 14 ft verification grid, and an AGi32-validated dedicated mirrored optimizer. Tennis uses the AGi32-validated Primary/Secondary Playing Area calculation model, 3 ft AFG plane and centered 20 x 20 ft verification grid. Tennis recommendations test practical 4/6/8-pole long-side layouts, one common automatic pole height starting at 40 ft, and symmetric equal-depth rack fans mirrored across the court; the dedicated Tennis path preserves that symmetry throughout fixture screening and optimization. Pickleball uses its AGi32-validated 64 x 34 ft surface, 3 ft AFG plane and centered 20 x 20 ft / 8-point verification grid. Pickleball recommendations use the same dedicated symmetric approach in Guided and Expert, testing practical 4/6/8-pole long-side layouts, one common automatic pole height starting at 35 ft and 1–6 heads per pole; passing layouts rank by fewest poles first. Among equal-pole passing layouts, a practical maintained-average design within 15% above the selected Class target outranks an unnecessarily overlit design; lower connected watts and lower boundary light then rank ahead of raw head count. Grossly overlit passing choices above 150% of target are recommendation fallback-only whenever a practical passing choice uses the same or fewer poles. Hockey recommendations test practical 4/6/8-pole long-side layouts, one common 40 ft+ pole height, and true mirrored opposite-head ordering. Every pole and head remains individually editable afterward.
ANSI/IES RP-6-24 sport criteria are loaded by Application and Class of Play. Outdoor Hockey uses the 0 ft playing surface; Soccer, Football, Baseball, Tennis and Pickleball use 3 ft AFG. Tennis Class criteria are evaluated on its Primary Playing Area with a separate Secondary Playing Area average check. Pickleball uses the validated centered 20 x 20 ft / 8-point verification grid on its 64 x 34 ft playing surface.
For validated Soccer and Football workflows, this can re-aim/re-tilt the same exact selected/uploaded IES without changing photometry. Baseball already runs its dedicated infield/outfield zone-aware aiming search. Outdoor Hockey re-runs its dedicated mirrored optimizer so opposite head assignments remain balanced. Tennis and Pickleball re-run their dedicated symmetric optimizers so equal-depth rack symmetry and opposite-sideline mirroring are preserved.
Select an exact fixture; its manufacturer IES loads automatically when available (or Upload IES), then run the recommendation. Leave Recommendation Pole Height blank for Auto, or enter an exact common height to test. After a layout is created, Refine Selected Fixture Aims can optimize its individual aim points and tilts without changing photometry.
Let LSW find a suitable sports floodlightWe will use your field size, Class of Play and pole-height limit to search eligible Canadian Genlyte outdoor fixtures and propose a practical starting layout.
How the recommendation works

The search uses exact manufacturer IES photometry, screens sports/flood products, and compares candidate layouts against the selected horizontal lighting criteria. Advanced mixed-optic and aim optimization remain available in Expert mode.

Fixture Recommendation BetaScreens eligible Canadian Genlyte Product Type 1200 flood / sports-flood / spot-lighting Point by Point rows only, excluding roadway and general area families. At 50 ft and higher sports pole-height screens, candidates below 40,000 lm are skipped. For speed, every eligible fixture family gets an exact-IES opportunity, but the first-pass search tests only a small distribution-diverse representative set and a sparse Auto-height screen instead of automatically exhausting every catalog configuration. Mixed-Optic Optimization Beta can then search exact compatible distributions within a shown family/output/CCT package and refine aims.
Ready to search the Genlyte outdoor catalog. Candidates without an exact usable IES are skipped.
Fixture Optimization BetaExpert-mode first-pass failures are screening candidates, not recommendations. Use Optimize This Fixture on a card, or Optimize Top Candidate here. The tool searches exact compatible distributions when available and automatically falls back to exact-fixture aiming when only one exact IES distribution can be resolved. A candidate is labeled Recommended only after the completed optimization path meets the current criteria.
Find fixture candidates first. A failing Expert-mode screen is not a recommendation until optimization succeeds. Optimize Top Candidate or a specific card to run the best available exact-photometry path; Optimize + Rank All compares all displayed candidates.
Review the optimized layoutGuided mode has already balanced the automatic sports head count and optimized individual aiming before this screen opens. You can re-optimize the aiming, or open the same pole/head controls used in Expert mode and adjust individual heads yourself.
Tip: select a head and drag its blue aim point on the field, or edit Aim X / Aim Y, Orientation and Tilt in the Head / Aim panel.
Field / site layout
Mirror assembliesCopies pole, crossbar, heads, fixture/optic selections and mirrored aim points.
Layout viewClick a pole, blue aim point, elevation head or schedule row to focus it. Selected pole is the normal aiming view; All heads remains available as a dense diagnostic view.
Calculation points
Total Site IsolinesCombined light from the complete layout after calculation.
Contours use the current total Direct Point by Point grid. While Focus selected head is active, total-layout isolines are temporarily hidden so the selected head footprint cannot be confused with a field-wide contour.
Fixture Design IsolinesUse these while placing and orienting individual heads. Selected heads can stay visible for comparison.
Shown heads: none
AGi32-style aiming aid: while this is on, every head you select is added to the plan and its four photometric contours stay visible while you select and aim additional heads. Use Clear active head to remove only the selected head, or Clear all shown heads to start over. Each contour uses that head's exact IES, live mounting height, aim/orientation/tilt/spin, calculation plane and LLF.
0 points
Soccer, Football and Baseball class criteria are evaluated at 3 ft AFG. The calculation-plane height remains editable. Baseball presets use preset-aware Point by Point grids clipped to the actual playing area and report infield and outfield separately.
Calculation point Pole Aim point / line Approx. geometric beam footprint Total-layout isolines Per-head design isolines Site/spill boundary
Selected pole elevation / rack
Selected pole head scheduleClick a row to focus that head in the plan and elevation views.

Check lighting & boundary

Average—fc
Minimum—fc
Maximum—fc
Avg / Min—
Max / Min—
CV——
Max boundary—fcINFO
Direct calculationType C, TILT=NONE IES direct horizontal illuminance is active. Multiple heads are summed and each fixture/head LLF is applied individually.
Boundary lightDirect horizontal illuminance is calculated around the entered site boundary. Enter an optional project limit to include it in recommendation PASS/FAIL. This is a preliminary boundary check, not a complete light-trespass compliance model.
GlareBUG/glare observer calculations remain reserved for a later validated stage.
AGi32 validatedDirect Point by Point matches AGi32 Direct Only in controlled OFD-XL tests and full-layout sports benchmarks. Soccer Class I: 84 PFF Gen2 heads / 693 identical points, Outdoor Avg 86.57 fc vs AGi32 86.72 fc, Max/Min 1.70 in both, CV 0.117 vs 0.12 displayed. Football Class I: 360 × 160 ft, 80 PFF Gen2 heads / 72 identical points, Outdoor Avg 105.02 fc vs AGi32 105.19 fc, Max/Min 1.26 in both, CV 0.060 vs 0.06 displayed. Baseball Class III: 18 Infield + 116 Outfield points; Infield Avg 52.16 vs 52.26 fc AGi32, Max/Min 1.65 both, CV 0.156 vs 0.16; Outfield Avg 37.41 vs 37.46 fc, Max/Min 2.46 both, CV 0.2077 vs 0.21 displayed. Baseball Class I v0.9.03 benchmark: 128 PFF Gen2 heads at 90 ft on the same 18/116 point zones; Infield Avg 189.87 fc vs AGi32 190.33 fc, Max/Min 1.27 both, CV 0.0697 vs 0.07 displayed; Outfield Avg 100.04 fc vs AGi32 100.17 fc, Max/Min 1.68 both, CV 0.122 vs 0.12 displayed. 60 ft Youth Class III measurement-grid benchmark: 25 Infield + 75 Outfield points; Infield Avg 127.17 fc vs AGi32 127.38 fc, Max/Min 1.97 both, CV 0.167 vs 0.17 displayed; Outfield Avg 100.77 fc vs AGi32 100.91 fc, Max/Min 2.47 vs 2.49 displayed, CV 0.196 vs 0.20 displayed. 70 ft Youth Class III measurement-grid benchmark: 25 Infield + 65 Outfield points; Infield Avg 92.31 fc vs AGi32 92.44 fc, Max/Min 1.94 vs 1.96, CV 0.169 vs 0.17 displayed; Outfield Avg 68.24 fc vs AGi32 68.39 fc, Max/Min 2.41 vs 2.42, CV 0.195 vs 0.20 displayed. Pickleball Class III benchmark: 64 x 34 ft playing surface, 8 FLDL-A23-740-RNF luminaires at 35 ft, LLF 0.90 and 8 identical centered points; Outdoor Avg/Min/Max 50.39/45.91/54.88 fc versus AGi32 50.90/46.3/55.5 fc, Avg/Min 1.10 in both, Max/Min 1.20 in both, and Outdoor CV 0.089 versus AGi32 0.09 displayed.
Not calculated, or layout changed since the last calculation.

Direct Only: no reflected light, obstructions, terrain, glare rating, vertical-illuminance compliance or full photometric light-trespass compliance calculation. Sports and Free Form boundary results, when used, are direct horizontal illuminance at the entered boundary check line. Soccer and Football recommendations are validated horizontal maintained-light starting recommendations. Baseball is a zone-aware recommendation workflow with Regulation Classes I–III plus the 60 ft and 70 ft Youth Class III measurement grids AGi32-validated; Regulation Class IV and 80 ft Youth validation continue. None is a sealed/compliance design.

AGi32 validation exportOptional advanced validation. Available after the current lighting calculation is complete.

Outdoor lighting report

Page 1 presents the centered Point by Point calculation, Fixture Schedule, Calculation Schedule and title column. Site reports include the site plan background plus a separate Head Orientation Schedule for every Site head; aiming information is added only when the layout actually uses aimed fixtures.

Would you like any follow-up from LSW?These choices apply to this completed layout. Your contact information was already recorded at the start of the Quick Layout.
If Quote is Yes, LSW's quote team receives this layout and its Bill of Materials so a quote can be prepared. If Salesperson is No, no salesperson contact is requested. LSW does not share your contact information with third parties for sales or marketing.
Generate the report to preview and download the PDF.

LSW Guided Outdoor Lighting Layout Tool