Choose the application first. We will load the correct geometry, calculation rules and fixture search.
A site plan (DXF, PDF or image) gives you a plan to work directly on. If you do not have one, we will start from editable dimensions.
You can keep a preferred family, or leave the family open and let Quick Layout compare eligible choices.
Quick Layout can compare exact IES-backed fixtures and optimize the layout, or you can choose the exact fixture yourself.
Only the information needed to build the first layout is shown here. Everything remains editable later.
The search uses exact manufacturer IES photometry, screens sports/flood products, and compares candidate layouts against the selected horizontal lighting criteria. Advanced mixed-optic and aim optimization remain available in Expert mode.
Direct Only: no reflected light, obstructions, terrain, glare rating, vertical-illuminance compliance or full photometric light-trespass compliance calculation. Sports and Free Form boundary results, when used, are direct horizontal illuminance at the entered boundary check line. Soccer and Football recommendations are validated horizontal maintained-light starting recommendations. Baseball is a zone-aware recommendation workflow with Regulation Classes I–III plus the 60 ft and 70 ft Youth Class III measurement grids AGi32-validated; Regulation Class IV and 80 ft Youth validation continue. None is a sealed/compliance design.
Page 1 presents the centered Point by Point calculation, Fixture Schedule, Calculation Schedule and title column. Site reports include the site plan background plus a separate Head Orientation Schedule for every Site head; aiming information is added only when the layout actually uses aimed fixtures.
Generated directly from the current live layout. Fixture marks match the F1, F2, F3… tags used on the Site plan and Fixture Schedule. This exact BOM data is also placed in the draft PDF and used with a quote request.
| Mark | Type | Item / Description | Catalog / Size | Optic | Qty |
|---|
Review the complete report before saving or printing it. PDF downloads the report exactly as the previous Generate PDF action did. Cancel returns to the Report screen without changing the layout.
You need a web browser, about 15 minutes, and ideally a site plan. Everything else is filled in for you and can be changed later.
Have ready:
Opening the tool:
Click something on the plan and the settings panel on the right switches to it. In Guided mode some tabs and sections stay hidden until the step needs them.
In Guided mode a parking lot takes nine steps. The step list on the left shows where you are; use Continue → and ← Back to move between steps.
First, answer the setup questions:
Then build the layout:
Starting light levels by area type (from current IES recommended practices; your project or local authority may require different values):
| Area type | Target average | Max/Min limit | CV limit |
|---|---|---|---|
| Parking area | 2.0 fc | 4.0 | 0.35 |
| Building entrance / drop-off | 2.0 fc | 5.0 | 0.35 |
| Loading / service area | 2.0 fc | 5.0 | 0.35 |
| Crosswalk | 1.9 fc | 4.0 | 0.35 |
| Drive lane / internal roadway | 1.0 fc | 4.0 | 0.35 |
| Sidewalk / pedestrian walkway | 1.0 fc | 5.0 | 0.35 |
| General outdoor site area | 1.0 fc | 5.0 | 0.35 |
| Park / plaza / gathering area | 0.8 fc | 10.0 | 0.50 |
| Landscape / feature area | 0.5 fc | 10.0 | 0.50 |
An area passes when its average is between the target and 15% above it, and its Max/Min and CV are at or below their limits.
Every head needs a fixture with its manufacturer IES (photometry) file before the lighting can be calculated. You can let the tool choose, or pick one yourself in the Fixture tab on the right.
Let the tool choose: click Auto Find Fixtures. It tests eligible area lights on your poles and heads against every calculation area and lists the results, best first. Auto Find Fixture for Selected Head does the same for one head and leaves the rest alone.
Pick your own:
Things you may see:
Light Loss Factor (LLF) allows for dirt and lamp aging over time. It starts at 0.90 for each head and can be changed in the Fixture tab.
Area lights only turn; floods and spots turn and tilt. Orientation is the compass direction a head faces. Tilt is how far it is raised from pointing straight down, up to 62.5°.
| Fixture type | What you can set | How |
|---|---|---|
| Area, site and roadway lights | Orientation only (always level) | Drag the yellow handle, or type in the Orientation box |
| Floods and spots | Orientation and tilt | Drag the blue aim point, type Orientation and Tilt, or use Aim Head with Isolines |
To aim a flood:
Several heads on one pole: in the Site heads box choose 2, 3 or 4 heads and a fan spread, then click Apply Heads. Ctrl+Click (Cmd+Click on a Mac) selects several heads, but turning and dragging always change just the active one.
Photometric Spin rotates the light pattern of an uneven optic without moving the aim point. Most users never need it.
Click Calculate Lighting to measure the light at every calculation point. Each area then shows its numbers and a pass or fail. Any change to poles, heads, fixtures or areas clears the results, so calculate again before the report.
| Result | What it means | Better when |
|---|---|---|
| Average | The average light level on the ground, in foot-candles (fc) or lux | Between the target and 15% above it |
| Minimum / Maximum | The darkest and brightest points | — |
| Max/Min | Brightest point divided by darkest point | Lower (more even) |
| Avg/Min | Average divided by darkest point; shown for reference | Lower |
| CV | How much the light varies across the area | Lower (more even) |
If an area fails, the message under it names the measure that failed and the usual fix:
Seeing the light on the plan: open 3. Advanced display & layout tools.
Sports work the same way as a site, except the field, calculation points and light levels are set up for you. Choose Outdoor Ice Hockey, Soccer, Football, Baseball, Tennis or Pickleball on the first question, then pick the Class of Play.
| Class of Play | Typical use | Soccer target | Football target |
|---|---|---|---|
| Class I | Professional / major competition | 75 fc | 100 fc |
| Class II | Collegiate / high-level competition | 50 fc | 50 fc |
| Class III | High school / club / amateur | 30 fc | 30 fc |
| Class IV | Recreational / training / social | 20 fc | 20 fc |
Good to know:
Expert mode shows every control at once, so you can build and tune a layout by hand. Switch with Switch to Expert at the top. Your layout, fixtures and results carry over, and you can switch back to Guided at any time.
Building the layout by hand:
The Pole / Crossbar tab (select a pole first):
| Setting | What it does |
|---|---|
| Position X / Y | Where the pole stands. You can also drag it on the plan. |
| Pole / Upper Rack Height | Mounting height of the top fixtures. It can't exceed the project maximum. |
| Crossbar Width | Width of a single crossbar. Multi-tier sports racks are sized for you. |
| Vertical Tier Spacing | Gap between crossbar tiers. Leave blank to use the fixture size plus clearance. |
| Crossbar Orientation | Which way the crossbar faces, in degrees. |
On the Head / Aim tab, Crossbar Offset moves a head along its crossbar. Beam Angle only changes the footprint drawn on the plan; the calculation always uses the IES file.
Finding and optimizing sports fixtures:
| Button | What it does |
|---|---|
| Find Recommended Fixture | Tests eligible sports floodlights with their exact IES files and lists candidates. In Expert, the first list is a quick screen, not a recommendation. |
| Optimize for | Chooses what "best" means: best overall, fewest fixtures, or lowest total watts. |
| Optimize This Fixture | Runs the full optimization, including compatible optics and aiming, on one candidate. |
| Optimize Top Candidate | The same, for the top candidate in the list. |
| Optimize + Rank All | Optimizes every candidate and ranks them. Passing designs always rank first. |
| Optimize Aims + Mix | For a near-miss: keeps the poles fixed and fine-tunes each head's aim and optic. |
| Optimize Final Layout | For a stubborn fail: also tries other pole counts, heights and setbacks. Slower. |
| Use Anyway (Expert) | Applies a layout that doesn't meet every target. It is not a recommendation. |
| Recommend Sports Layout | Builds a layout using the fixture and IES on the selected head. |
| Refine Selected Fixture Aims | Re-aims the current layout with the same fixture, without changing photometry. |
Leave Recommendation Pole Height blank to let the tool pick the lowest height that works, or type one height to test only that height.
Refining a Site layout (in 2. Calculation areas & light levels):
Calculation and boundary settings (in 3. Advanced display & layout tools and the project settings):
| Setting | What it does |
|---|---|
| Point spacing | Distance between calculation points. Smaller gives more detail but calculates more slowly. |
| Minimum edge inset | Keeps points this far in from the area edge. |
| Calculation plane height | Height above the ground where light is measured. Sports use 3 ft. |
| Field / Spill Boundary Offset | Distance from the field edge to the line where spill light is checked. |
| Boundary light limit | Optional maximum light at that line. Left blank, boundary light is reported only. |
View tools:
Checking in AGi32: after calculating, Export AGi32 Validation ZIP saves the IES files, fixture locations and aiming, calculation points, expected results and step-by-step instructions, so the layout can be checked in AGi32.
When the lighting passes, the Report screen turns your layout into a PDF and can send it to LSW for a quote.
Make the report:
The report includes the plan, the point-by-point values, each area's results and targets, a fixture schedule, a head orientation schedule and the bill of materials. Pass/fail is shown in the tool only, not on the PDF.
Bill of Materials: click Bill of Materials to see fixtures, poles by height and crossbars counted from your layout. Download BOM CSV saves it for a spreadsheet.
Ask for a quote:
Save your work: click Save Project at the top. It downloads a .lsw file with everything in it: plan, areas, poles, heads, fixtures, IES files and settings. Next time, click Open Project and choose that file. Calculate the lighting again after opening, before making a new report.
Most problems come from the plan scale, a missing IES file, or results that need recalculating. For tips on the step you're on, click Step help in the corner.
| Problem | What to do |
|---|---|
| I only have a DWG file | Save it from your CAD program as an ASCII DXF, or print the site plan sheet to PDF. |
| My DXF loads tiny or huge | Change DXF units (feet, inches, metres, millimetres), or use Measure / Scale and Calibrate Scale. |
| Part of my DXF is missing | Change DXF fit to All model geometry. |
| Distances on my PDF look wrong | Measure a dimension you know, type its real length and click Calibrate Scale. Measure a second one to confirm. |
| Calculate Lighting won't run | Every head needs a fixture with IES loaded ✓. Look for heads without a fixture, or click Retry / Refresh IES. |
| It asks me to choose a photometry file | The manufacturer supplies several IES files in one download. Pick the one that matches your fixture's wattage and colour. |
| "No exact IES" for a fixture | Choose another configuration from the same family, or use Upload IES with the manufacturer's file. |
| I can't find floods, wall packs or bollards | Tick Include floods, wall, canopy, bollard and landscape fixtures in the Fixture search. |
| I can't tilt a head | Only floods and spots tilt. Area and site lights always sit level. |
| No isolines show | Calculate the lighting first for Total Site isolines. For a single head, click Aim Head with Isolines. |
| Nothing passes | Check the area targets, add a pole where the plan is dark, move poles toward the middle of large areas, or try a different family or colour temperature. |
| My results disappeared | A change cleared them. Click Calculate Lighting again. |
| The report shows only part of my site | Click Zoom Extents before generating the report. |
| Word | Meaning |
|---|---|
| Aim point | The spot on the ground a flood is pointed at. Shown as a blue dot. |
| BOM | Bill of materials: the list of fixtures, poles and crossbars to buy. |
| Calculation area | A part of the plan where light is measured, such as a parking area or walkway. |
| Calculation point | One spot where the tool measures the light. Points sit on a grid, usually 10 ft apart. |
| Class of Play | The level of sport (I to IV). Higher classes need more light. |
| CCT / colour temperature | How warm or cool the light looks: 3000 K is warm, 4000 K neutral, 5000 K cool. |
| CV | Coefficient of variation: how much the light varies across an area. Lower is more even. |
| Distribution (Type II–V) | The shape of the light on the ground. Type II is long and narrow, Type V is round. |
| fc (foot-candle) | A unit of light on a surface. 1 fc is about 10.76 lux. |
| Head | One fixture on a pole. A pole can carry several heads. |
| IES file | The manufacturer's data file describing exactly how a fixture spreads its light. |
| Isoline | A contour line joining points with the same light level. |
| LLF | Light loss factor: allows for dirt and lamp aging. 0.90 means 90% of new output. |
| Max/Min | Brightest point divided by darkest point. Lower is more even. |
| Orientation | The compass direction a head faces. |
| Tilt | How far a flood is raised from pointing straight down. The limit is 62.5°. |
Results are a preliminary design. Fixture choice, layout, pole structure and code compliance must be checked before installation.
Nothing in the manual matches that. Try a shorter word, or open ? Help / About.
LSW Outdoor Quick Layout v0.10.140
Copyright © 2026 Dean Lind. All rights reserved.
Licensed to LSW Lighting for authorized business use.
It helps you lay out outdoor lighting quickly. You place poles, choose fixtures and aim them, and the tool calculates how much light lands on the ground at each point using the manufacturer's exact photometry (IES) file. When the layout works, you can print a draft report, see the bill of materials and ask LSW for a quote.
It handles parking lots and other outdoor sites, plus soccer, football, baseball, outdoor hockey, tennis and pickleball fields. Results are a preliminary design. Final design must be checked before anything is installed.
Enter your contact information first. Then pick a mode:
Both modes work on the same project, so you can switch at any time (Switch to Expert at the top) without losing anything. Click Step help in the corner for tips on the step you are on.
An area passes only when its average light is between its target and 15% above it, so it is neither too dark nor over-lit.
Save Project downloads a .lsw file with everything in it: plan, areas, poles, heads, fixtures, IES files and settings. Open Project loads it again later or on another computer. Calculate the lighting again after opening, before making a new report.
After calculating, Export AGi32 Validation ZIP creates a package with the IES files, fixture locations and aiming, the calculation points, the expected results and step-by-step instructions, so the layout can be checked in AGi32.
The calculation was checked against AGi32 (Direct Only) using the same fixtures, aiming and points. The averages matched within about 1%:
Glare, spill light, vertical light levels and TV broadcast requirements are not checked yet.