Use manufacturer Genlyte photometric data to estimate a regular fixture layout. Final lighting design should be verified by a qualified lighting professional.
Quick Lighting Layout Help
What this tool does: Creates a preliminary Genlyte point-by-point lighting layout from manufacturer photometric data, your room geometry and your entered design assumptions. It is a planning tool, not a final engineered lighting design.
Step-by-step instructions with a search box.
Quick start
Enter your contact, project and room information.
Enter the mounting height and desired target light level.
Choose a Genlyte product that is marked PBP available.
Review fixture photometric orientation and point spacing.
Calculate, review the PBP, then generate the report PDF.
Workplane Height
The height above the floor where illuminance is calculated. The default 2.5 ft is approximately a desk/work-surface height. Use 0 ft when the floor itself is the calculation plane.
Target Light Level
The desired average illuminance on the workplane, entered in footcandles (fc). The target is used to estimate fixture quantity; the completed point-by-point result shows the actual calculated average, minimum and maximum.
Ceiling, Wall and Floor Reflectance
The percentage of light reflected by each room surface. Higher values represent lighter, more reflective finishes. The defaults are 80% ceiling, 50% walls and 20% floor. Use realistic values because reflected light affects the calculated result.
Light Loss Factor (LLF)
A multiplier from 0 to 1 used to estimate maintained rather than initial light levels. A lower LLF reduces the calculated maintained footcandles. The default is 0.90; use a project-specific value when one is known.
Genlyte Product / PBP Available
The product catalog comes from the Genlyte master catalog. A fixture must have supported IES photometric data to run a point-by-point calculation. Some Genlyte records provide a ZIP bundle of IES files instead of one file, and some fixtures have no IES link of their own but their Genlyte family page publishes a Family IES collection. The calculator opens the bundle and uses the matching file when it can identify it safely; otherwise it lists the files so you can choose yours. Products without supported IES data may appear in the catalog but are marked PBP unavailable.
Point Spacing and Calculation Points
Point Spacing controls how closely the workplane is sampled. Smaller spacing creates more calculation points and more detail, but also takes longer. The tool shows the resulting calculation grid and number of points before you calculate.
Fixture Photometric Orientation
This rotates the fixture's IES light distribution within the room. 0° Along Room Length places the IES 0° photometric plane along the room length. 90° Along Room Length rotates the photometry a quarter-turn so the IES 90° plane runs along the room length. This is a photometric orientation, not necessarily the visible long side of the fixture. Symmetric distributions may show little or no change.
CU / RUF
The utilization value estimates how much of the fixture output contributes to the room/workplane after considering the photometric distribution, room proportions and surface reflectances. The tool displays CU/RUF terminology because absolute-photometry fixtures are technically described using room utilization factor/utilance.
IES Spacing Criterion (SC)
The spacing criterion from the IES data is used as a screening guideline for a regular fixture array. The tool converts it into an approximate maximum fixture spacing based on mounting height above the workplane. It is not a hard pass/fail rule; review the actual PBP uniformity for the layout.
Fixture Quantity and Layout
The tool first calculates the minimum fixture quantity needed for the target light level from the room utilization. It then always places fixtures in a complete, evenly spaced rectangular grid. When the minimum quantity does not fill a complete grid, it is rounded up to the smallest grid with reasonably even spacing that stays within the fixture's spacing guideline, so the result can be slightly above target. The − and + buttons step to the next smaller or larger complete grid.
Understanding the PBP Results
Average is the mean calculated footcandles across the workplane. Minimum and Maximum are the lowest and highest calculated points. Avg / Min is a uniformity ratio; values closer to 1.00 indicate a more even layout. Always review the PBP pattern as well as the summary numbers.
Calculation Basis & Limitations
Results depend on the selected manufacturer's IES file, room dimensions, mounting/workplane heights, reflectances, LLF, orientation and point spacing. The calculation estimates direct and room-reflected light but does not model every real-world condition such as furniture, partitions, obstructions, daylight, unusual geometry or field tolerances. Final design should be verified for the actual project.
User Manual
Before you start
You need a web browser and about five minutes. The tool turns your room size and a Genlyte fixture into a point-by-point lighting layout and a PDF report. Most settings start with typical values that you can change.
Have ready:
Your contact details: name, company, email and phone. They are required before the tool unlocks. No LSW salesperson contacts you unless you ask on the Report section.
The room size in feet: length, width and ceiling height.
The mounting height of the fixtures: the same as the ceiling for recessed troffers, lower for pendants and high bays.
The light level you want, in foot-candles (fc), if the project specifies one.
A fixture, if the project specifies one. If not, you can search the Genlyte catalog by family, lumens or watts.
Enter your contact details in 1. Contact information. The rest of the tool unlocks when all four are filled in.
To continue a layout you saved before, click Open Project in that section and choose your .lsw file instead.
The screen at a glance
Work down the middle of the page from 1 to the Report. The panels on either side show the fixture you selected and its spec sheet. User Manual and ? Help / How This Tool Works are always at the top, and each ? beside a field opens help for that setting.
Quick start: light a room
Contact information. Enter your name, company, email and phone.
Project and room. Type a project name, then the room length, width, ceiling height and mounting height. Enter the Target Light Level you want in foot-candles.
Choose a Genlyte product. Type in Search (a family name or catalog number), or set Brand, Approx. Lumens or Approx. Watts. Click a product marked PBP available.
Calculate. Leave Point Spacing at 4 ft and click Calculate Point-by-Point Layout.
Check the results. Compare the Average with your target. Use − or + to try another quantity, then click Recalculate PBP.
Report. Answer the quote and salesperson questions if you want follow-up, then click Generate Lighting Report PDF. Click Save Project to keep working on it later.
Describing the room
Enter the room in feet. Fields marked * are required; the rest start with typical values you can leave as they are.
Field
What it means
What to enter
Project Name *
The name printed on your report
For example, Smith Office Renovation
Room Name
Which room this layout is for
Optional, for example Open Office 2nd Floor
Room Length (ft) *
The long side of the room
For example, 40
Room Width (ft) *
The short side of the room
For example, 30
Ceiling Height (ft) *
Floor to ceiling
For example, 9
Mounting Height (ft) *
Floor to the bottom of the fixture
The ceiling height for recessed fixtures; lower for pendants and high bays
Workplane Height (ft) *
The height where the light is measured
2.5 ft for desks (the default); 0 for floors such as warehouses
Target Light Level (fc) *
The average light level you want
Ask your designer; offices are often 30–50 fc
Ceiling / Wall / Floor Reflectance
How much light each surface bounces back, in %
80 / 50 / 20 (the defaults) suit a light ceiling, medium walls and a darker floor
Light Loss Factor (LLF)
Allows for dirt and fixture ageing
0.90 (the default) unless the project gives another value
Lighter finishes reflect more light, so use realistic reflectances: they change the result.
Choosing a fixture
The product list stays hidden until you type in Search or set a filter. Each product shows whether it can be calculated:
Label
What it means
PBP available
The manufacturer's IES file is ready, so the fixture can be calculated point by point
PBP via family IES collection
The product has no IES file of its own, so the file comes from the IES collection on its Genlyte family page
PBP unavailable — no supported IES
Genlyte publishes no usable photometry for this product (common for accessories). Choose another product
Click a product to select it. Its details appear in the Selected Fixture panel on the left and its spec sheet on the right, and the tool loads its photometry. Three things can appear under the fixture:
Choose the photometry file. Some manufacturers supply one bundle of IES files for a whole family (different lumen packages, colour temperatures or trims). If the tool can't tell which file is your exact fixture, it lists them, closest matches first. Type in the filter box (for example 4000 or 2x4), pick your file and click Use this file.
Change file. After a file is chosen or matched, this link lets you pick another one from the same bundle.
Colour temperature for the calculation. Fixtures with selectable colour temperature (for example ModuLyte ColorSelect) let you choose which one to calculate. The tool starts at 3500 K.
If the manufacturer doesn't publish your exact trim, the tool uses the closest published version and says so on screen and in the PDF.
Checking the lighting
Two settings sit in 4. Calculate:
Point Spacing (ft) is how far apart the light-level checks are. 4 ft is the default. Smaller spacing gives more detail but takes longer; the Calculation Grid box shows how many points will be checked.
Fixture Photometric Orientation turns the fixture's light pattern 90° in the room. Use 90° when the fixtures need to run across the room. Round, symmetric fixtures may show no difference.
Click Calculate Point-by-Point Layout. In a few seconds the Lighting Layout Results appear:
Result
What it means
Better when
Average
The average light level on the workplane, in foot-candles
At or a little above your target
Minimum / Maximum
The darkest and brightest points
—
Avg / Min
Average divided by the darkest point
Closer to 1.00 (more even)
Layout
The fixture grid, for example 5 × 3 = 15 fixtures, and the spacing between them
—
IES SC guideline
The widest spacing the fixture's light pattern suits. A ⚠ means the spacing is wider than that
No ⚠
The plan below the numbers shows each fixture to scale and the light level at every point.
Changing the quantity: the tool works out how many fixtures your target needs, then rounds up to the nearest complete, evenly spaced grid, so the average can land a little above your target. Use − and + beside Fixture Quantity to step to the next smaller or larger complete grid, then click Recalculate PBP.
After any change to the room, the settings or the fixture, click Recalculate PBP so the results match.
Report, quote and saving
Ask for follow-up (optional). In the Report section, both questions start at No:
Would you like LSW to prepare a quote from this layout? Choose Yes to send the layout to LSW's quote team.
Preferred distributor partner (optional) appears when you choose Yes. Type the distributor and branch you buy through, or leave it blank.
Would you like an LSW salesperson to call you? Choose Yes only if you want a call.
Make the report. Click Generate Lighting Report PDF. The PDF downloads straight away. If a security check appears above the button, complete it first. The report includes your project, room and fixture details, the plan with the light level at every point, and the results. A second page explains how the layout was calculated and its limits.
Save your work. Click Save Project. It downloads a .lsw file with your contact details, room, fixture, chosen photometry file and colour temperature, quantity and follow-up answers. Next time, click Open Project in 1. Contact information and choose that file. The tool fills everything back in, finds the fixture in the current catalog and recalculates. Older project files saved as .json still open.
Troubleshooting
Most problems come from a fixture with no photometry, or results that need recalculating.
Problem
What to do
The room and fixture sections are greyed out
Fill in all four contact fields in 1. Contact information.
No products are listed
Type in Search or set a Brand, Lumens or Watts filter. The list stays hidden until you do.
PBP unavailable — no supported IES
Genlyte has no usable photometry for that product. Choose a similar fixture marked PBP available.
"Genlyte does not publish photometry for …"
The product has no IES file and its family page has no IES collection. Choose another fixture.
It asks me to choose a photometry file
The manufacturer supplies several IES files in one download. Pick the one that matches your fixture's lumens and colour, then click Use this file.
"The previously chosen photometry file … is no longer in the manufacturer bundle"
The manufacturer updated its files. Choose the file again from the list.
"The manufacturer photometric file could not be retrieved"
The manufacturer's site did not respond. Wait a moment, then select the fixture or click Calculate again.
The average is well above or below my target
Use − or + to change the grid, then click Recalculate PBP.
A ⚠ shows beside IES SC guideline
The fixtures are further apart than their light pattern suits. Add fixtures with +, or try a fixture with a wider distribution.
My results don't match a change I made
Click Recalculate PBP.
"That file is not an Indoor Quick Lighting Layout project"
Open a .lsw file saved from this indoor tool. Outdoor project files only open in the outdoor tool.
Glossary
Word
Meaning
Avg / Min
Average divided by the darkest point. Closer to 1.00 is more even.
CCT / colour temperature
How warm or cool the light looks: 3000 K is warm, 4000 K neutral, 5000 K cool.
CU / RUF
How much of a fixture's light reaches the workplane in this room.
Family IES collection
The bundle of IES files published on a Genlyte family web page.
fc (foot-candle)
A unit of light on a surface. 1 fc is about 10.76 lux.
IES file
The manufacturer's data file describing exactly how a fixture spreads its light.
LLF
Light loss factor: allows for dirt and fixture ageing. 0.90 means 90% of new output.
Mounting height
Floor to the bottom of the fixture.
PBP (point by point)
Checking the light level at a grid of points across the room, rather than estimating one average.
Photometry bundle
One ZIP file holding many IES files for a product family.
Reflectance
The share of light a surface bounces back. A white ceiling reflects about 80%.
Spacing criterion (SC)
The widest fixture spacing that still gives even light, from the IES file.
Workplane
The surface where light is measured, usually desk height (2.5 ft).
Results are a preliminary design. Fixture choice, layout and code compliance must be checked before installation.
Nothing in the manual matches that. Try a shorter word, or contact your LSW representative.
1. Contact information
Your privacy matters. Your contact information is used to prepare this layout, appears in the Prepared For section of the PDF, and is kept within LSW for administering the Quick Lighting Layout service. LSW will not share your contact information with third parties for sales or marketing. No LSW salesperson will contact you unless you request it later in the Report section. For security and audit purposes, the IP address used to generate the report is recorded.
Returning to a saved Quick Lighting Layout?Open a project file you saved earlier to pick up right where you left off. Your contact details, room, fixture and layout are restored and recalculated.
Complete all four contact fields to unlock the calculator.
2. Project and room
3. Choose a Genlyte product
4. Calculate
Calculation Grid—
Rotate fixture photometry in the room. Use 90° when the fixture or light distribution needs to run across the room instead of along its length. Symmetric fixtures may show little or no change.
Lighting Layout Results
Average—
Minimum—
Maximum—
Avg / Min—
Fixture Quantity
Report
Choose any optional LSW follow-up, then generate your PDF.
Optional LSW assistance
Quote: Yes sends a request to the LSW quote team; Quote: No sends no quote request. Salesperson: Yes asks an LSW salesperson to contact you; Salesperson: No means no sales call is requested.
Save Project downloads a project file to your computer. Use Open Project at the top of this page to continue later, or share the file with your LSW representative.
Preliminary design-assistance tool. Results depend on user-entered project information and manufacturer photometric data. To the extent permitted by law, the software provider and distributor are not responsible for errors or losses arising from inaccurate or incomplete inputs, manufacturer data, field conditions, obstructions, furniture or equipment, daylight, glare, ceiling or mounting conditions, codes, or other project-specific requirements. Final fixture selection, layout, mounting, code compliance, and photometric performance must be independently verified before installation.
All rights reserved. Licensed to LSW Lighting.v1.0.35